Furnaces for heat treating, metal melting and soldering Steam curing system for precast and prestressed concrete block and pipe CO2 Generator for greenhouse applications Johnson Gas Appliance Company - Corporate Page
Blowers
Sturdy, dependable blowers with a reputation for efficient delivery
of constant air pressure and quiet operation
| Product Index| Pricing| Replacement Parts| Contact Us|

Number 1219 (left), Number 1204 (center), Number 1207 (right)

Specifications:

Blower
Number


R.P.M.'s


Delivery at
W. C.
Pressure

Outlet


Housing


Duty


Type Motor


Approx.
Shipping
Weight
1218*
(Flange Mount)
11,000 26 CFM
at 4" W. C.
1" Aluminum   1/30 hp. 115 Volt,
Single Phase-
Flange Mount
8 lbs.
1203
3,450 50 CFM
at 4" W. C.
1-1/2" Aluminum Cont. 1/3 hp. 115 Volt,
Single Phase
28 lbs.
1204
3,450 75 CFM
at 5" W. C.
1-1/2" Aluminum Cont. 1/3 hp. 115 Volt,
Single Phase
32 lbs.
1207 5,000 75 CFM
at 6.5" W. C.
1-1/2" Aluminum   1/7 hp. 115 Volt,
Single Phase
35 lbs.


* To obtain 1218 with air shutter, order 1219

| Product Index| Pricing| Contact Us|